Protective and Diagnostic Functions
7-
7
BUS
Option
Com Err
Option Communications Error
A communications error was detected
during a run command or while setting
a frequency reference from a Commu-
nications Option Card.
-
Check the communications
devices and communications sig-
nals.
E-15
SI-F/G
Com Err
SI-F/G Communications Error
Detected
A communications error was detected
when a run command or frequency
reference was set from an Option Card
and continuous operation was set for
the E-15 operation selection.
-
Check the communications sig-
nals.
E-10
SI-F/G
CPU down
SI-F/G Option Card CPU Failure
SI-F/G Option Card operation failed.
Digital Operator connection is faulty.
Disconnect and then reconnect the
Digital Operator.
Inverter control circuit is faulty.
Replace the Inverter.
CPF00
CPF
Digital Operator Communications
Error 1
Communications with the Digital
Operator were not established within 5
seconds after the power was turned
on.
The Digital Operator's connector isn't
connected properly.
Disconnect the Digital Operator
and then connect it again.
The Inverter's control circuits are
faulty.
Replace the Inverter.
CPU External RAM Fault
-
Try turning the power supply off
and on again.
The control circuits were destroyed.
Replace the Inverter.
CPF01
CPF01
Digital Operator Communications
Error 2
After communications were estab-
lished, there was a communications
error with the Digital Operator for
more than 2 seconds.
The Digital Operator isn't connected
properly.
Disconnect the Digital Operator
and then connect it again.
The Inverter's control circuits are
faulty.
Replace the Inverter.
CPF02
BB Circuit
Err
Baseblock circuit error
-
Try turning the power supply off
and on again.
The control circuit is damaged.
Replace the Inverter.
CPF03
EEPROM
Error
EEPROM error
-
Try turning the power supply off
and on again.
The control circuit is damaged.
Replace the Inverter.
CPF04
Internal
A/D Err
CPU internal A/D converter error
-
Try turning the power supply off
and on again.
The control circuit is damaged.
Replace the Inverter.
CPF05
External
A/D Err
CPU internal A/D converter error
-
Try turning the power supply off
and on again.
The control circuit is damaged.
Replace the Inverter.
CPF06
Option
error
Option Card connection error
The Option Card is not connected
properly.
Turn off the power and insert the
Card again.
The Inverter or Option Card is faulty.
Replace the Option Card or the
Inverter.
Table 7.1 Fault Displays and Processing (Continued)
Display
Meaning
Probable Causes
Corrective Actions
Summary of Contents for VARISPEED G7 -
Page 3: ......
Page 11: ...viii...
Page 33: ...1 16...
Page 105: ...4 20...
Page 349: ...6 154...
Page 375: ...7 26...
Page 413: ...10 24...
Page 417: ......