6
-138
During the copy operation, errors may occur. If an error is displayed, press any key to cancel the error display
and return to the 03-01 display.
Error displays and their meanings are shown below. (Refer to
Chapter 7
Errors when Using Digital Operator
Copy Function.)
Comparing Inverter Constants and Digital Operator Constant Set Values (VERIFY)
To compare Inverter constants and Digital Operator constant set values, make the settings using the following
method.
Error Display
Meaning
Inverter product code and Inverter software number are different.
Inverter capacity with which you are trying to copy, and the Inverter capacity stored in
the Digital Operator are different.
The Inverter control method in which you are trying to copy, and the Inverter control
method stored in the Digital Operator are different.
Comparison between the constant written to the Inverter and the constant in the Digital
Operator shows they are different.
After copying has ended, comparison between the sum value of the Inverter constant area
and the sum value of the Digital Operator constant area shows they are different.
Table 6.3 VERIFY Function Procedure
Step
No.
Digital Operator Display
Explanation
1
Press the MENU Key. and select advanced programming mode.
2
Press the DATA/ENTER Key, and select the constants monitor display.
3
Display o3-01 (Copy Function Selection) using the Increment Key and Decrement
Key.
4
Press the DATA/ENTER Key, and select the function setting display.
CPE
ID UNMATCH
VAE
INV. KVA UNMATC
CRE
CONTROL UNMATCH
CYE
COPY ERROR
CSE
SUM CHECK ERROR
** Main Menu **
-ADV-
Programming
Initialization
-ADV-
A1
- 00=1
Select Language
COPY Function
-ADV-
o3
- 01=0
Copy Funtion Sel
Copy Funtion Sel
-ADV-
o3-01=
0
COPY SELECT
*0*