Setting User Constants
Here, the procedure is shown to change C1-01 (Acceleration Time 1) from 10 s to 20 s.
Table 3.3 Setting User Constants in Advanced Programming Mode
Step
No.
Digital Operator Display
Description
1
Power supply turned ON.
2
MENU Key pressed to enter drive mode.
3
MENU Key pressed to enter quick programming mode.
4
MENU Key pressed to enter advanced programming mode.
5
DATA/ENTER pressed to access monitor display.
6
Increment or Decrement Key pressed to display C1-01 (Acceleration Time 1).
7
DATA/ENTER Key pressed to access setting display. The setting of C1-01
(10.00) is displayed.
8
Shift/RESET Key pressed to move the flashing digit to the right.
9
Increment Key pressed to change set value to 20.00 s.
10
DATA/ENTER Key pressed to enter the set data.
11
“Entry Accepted” is displayed for 1.0 s after the data setting has been con-
firmed with the DATA/ENTER Key.
12
The monitor display for C1-01 returns.
Frequency Ref
-DRIVE-
U1-02=60.00Hz
U1-03=10.05A
Rdy
U1-
01
=60.00Hz
** Main Menu **
-DRIVE-
Operation
** Main Menu **
-QUICK-
Quick Setting
** Main Menu **
-ADV-
Programming
Initialization
-ADV-
A1
-00=1
Select Language
Accel Time 1
-ADV-
(0.0
6000.0)
10.0Sec
C1
-00= 10.0Sec
Accel Time 1
-ADV-
C1-01=
0
010.0Sec
Accel Time 1
-ADV-
C1-01= 0
0
10.0Sec
Accel Time 1
-ADV-
C1-01= 00
1
0.0Sec
Accel Time 1
-ADV-
C1-01= 00
2
0.0Sec
Entry Accepted
-ADV-
Accel Time 1
-ADV-
C1-
01
= 20.0Sec