12 Communications Performance and Communications Load
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
12-2 A
d
ju
stin
g th
e Co
mm
un
icatio
ns L
o
ad
12
12-2-4 C
hanging the RPI
Method 3:
Changing a Particular Connection’s Packet Interval (RPI) Setting:
The usage of capacity without multicast filtering can be adjusted against the tag data link’s
allowable bandwidth by individually changing the packet interval (RPI) for a particular connec-
tion. In this case, the usage of capacity will also change for target device of the connection for
which the packet interval is changed.
(1) Click the Close Button at the bottom of the Usage of Device Bandwidth Dialog Box.
(2) Double-click the device that is set as the originator of the desired connection. The
Edit Device Parameters Dialog Box will be displayed.