8-29
8 Message Communications
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
8-2 Using
CIP Messa
g
e Co
mm
un
icati
ons
8
8
-2
-9 Response Cod
e
s
Examples of Additional Status When General Status Is 01 Hex
(Status of Connection Manager Object)
21
Write-once value or medium
already written
An attempt was made to write to a write-once medium
(e.g. WORM drive or PROM) that was previously written or
cannot be changed.
22
Invalid Reply Received
An invalid reply was received. (For example, the reply ser-
vice code does not match the request service code, or the
reply message is shorter than the minimum expected
reply size.) This status code is used for other causes of
invalid replies.
23 and 24
Reserved by CIP for future extensions.
25
Key Failure in path
The key segment that was included as the first segment in
the path does not match the destination module. The
object specific status must indicate which part of the key
check failed.
26
Path Size Invalid
The size of the path that was sent with the service request
is either too large or too small for the request to be routed
to an object.
27
Unexpected attribute in list
An attempt was made to set an attribute that is not able to
be set at this time.
28
Invalid Member ID
The member ID specified in the request does not exist in
the specified class, instance, and attribute.
29
Member not settable
A request to modify a non-modifiable member was
received.
2A
Group 2 only server general fail-
ure
This error code is reported only by group 2 only servers
with 4K or less of code space and only in place of Service
not supported, Attribute not supported, or Attribute not
settable.
2B to CF
Reserved by CIP for future extensions.
D0 to FF
Reserved for Object Class and
service errors
This range of error codes is to be used to indicate object
class-specific errors. This code range is used only when
none of the error codes in this table accurately reflect the
error that occurred. The additional code field is used to
describe the general error code in more detail.
General Sta-
tus (hex)
Additional Status (hex)
Description
01
0100
Connection in use or duplicate forward open.
01
0103
Transport class and trigger combination not supported.
01
0106
Ownership conflict.
01
0107
Connection not found at target application.
01
0108
Invalid connection type. There is a problem with either the
connection type or priority of the connection.
01
0109
Invalid connection size.
01
0100
Device not configured.
01
0111
RPI not supported. May also indicate problem with con-
nection time-out multiplier, or production inhibit time.
01
0113
Connection Manager cannot support any more connec-
tions.
01
0114
Either the vendor ID or the product code in the key seg-
ment does not match the device.
01
0115
Device type in the key segment does not match the device.
General sta-
tus code (hex)
Status name
Description of status
Summary of Contents for SYSMAC CJ1W-EIP21
Page 8: ...Manual Structure 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 42: ...Revision History 40 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 68: ...1 Introduction 1 26 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 266: ...9 FTP Server 9 20 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 431: ...Index 1 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 I Index...
Page 436: ...Index 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 Index...
Page 437: ......