13-33
13 Troubleshooting
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
13-5 Even
t L
o
g
s
13
13-5-2 Error T
a
b
le
34A9 0000 hex
Tag Data Link
Error
There were two or
more errors in a
connection as an
originator. The fol-
lowing are
excluded.
•
The power supply to the target
node is OFF.
•
Communications with the target
node stop.
•
The Ethernet cable for Ether-
Net/IP is disconnected.
•
The Ethernet cable for Ether-
Net/IP is disconnected.
•
Noise
S
34AA 0000 hex
Tag Refresh
Error
An unsupported
data area or
address range is
specified for the tag
data links.
•
An unsupported data area or
address range was specified for
the tag data links.
S
34AB 0000 hex
Basic Ether-
net Setting
Error
There is an illegal
TCP/IP setting.
•
The power was interrupted dur-
ing a download.
•
A communications error
occurred during a download.
S
34AC 0000 hex
IP Address
Table Error
The IP address
table information is
incorrect.
•
The power was interrupted dur-
ing a download.
•
A communications error
occurred during a download.
S
34AD 0000 hex
IP Router
Table Error
The IP router table
information is incor-
rect.
•
The power was interrupted dur-
ing a download.
•
A communications error
occurred during a download.
S
34AE 0000 hex
Routing Table
Error
The routing table
information is incor-
rect.
•
The power was interrupted dur-
ing a download.
•
A communications error
occurred during a download.
S
34AF 0000 hex
Ethernet
Advanced
Setting Error
There is an illegal
FINS setting.
•
The power was interrupted dur-
ing a download.
•
A communications error
occurred during a download.
S
34B0 0000 hex
Address Mis-
match
The host ID of the
local IP address is
inconsistent with
the FINS node
address. Or, the
last segment of the
local IP address is
inconsistent with
the setting on the
node address
switches.
•
The IP address conversion
method is set to automatic gen-
eration, but the host ID of the
local IP address is inconsistent
with the FINS node address or
the last segment of the local IP
address is inconsistent with the
setting on the node address
switch.
S
381C 0000 hex
Status Area
Layout Set-
ting Error
An error occurred in
the layout setting of
the EtherNet/IP
Unit.
•
There is an error in the layout
settings of the EtherNet/IP Unit.
S
54AE 0000 hex
Multiple
Switches ON
Error
More than one soft-
ware switch
changed to TRUE
at the same time.
•
More than one software switch
changed to TRUE at the same
time. Or, another software
switch changed to TRUE before
processing was completed for a
previous software switch.
S
U
84E0 0000 hex
IP Address
Duplication
Error
The same IP
address is used
more than once.
•
The IP address of the Ether-
Net/IP port is also used as the
IP address of another node.
S
Event code
Event name
Meaning
Assumed cause
Level
Reference
Maj
Prt
Min
Obs
Info
Summary of Contents for SYSMAC CJ1W-EIP21
Page 8: ...Manual Structure 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 42: ...Revision History 40 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 68: ...1 Introduction 1 26 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 266: ...9 FTP Server 9 20 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 431: ...Index 1 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 I Index...
Page 436: ...Index 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 Index...
Page 437: ......