![background image](http://html1.mh-extra.com/html/omron/sysmac-cj1w-eip21/sysmac-cj1w-eip21_operation-manuals_742257415.webp)
A-41
Appendices
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
A
-6 Diff
erences
in A
v
a
ilab
le Fu
nction
s Dep
endi
ng o
n
the CPU
Unit (NJ
or CJ Series)
App
A-6-2 Diff
eren
ces in Access Me
th
ods from the User Prog
ram
x: First I/O memory area address that is specified in the allocated CIO Area words.
Words x to x+15: Registered Target Node Table
The device variable that corresponds to all of the bits in words x to x+15 is given in the following
table.
User Settings Area
I/O memory location in CJ-
series CPU Unit
Device variable for the CJ-series Unit in NJ-series CPU Unit
Word address
Bit numbers
Variable name
Description
Words x to
x+15
00 to 15 in
each word
*_x.RegTargetSta.
TargetStaWd
Registered Target Node Table
(The functions of bits 00 to 15 in these words and
the functions of the device variable given on the left
correspond as given below.)
•
Bits 00 to 15 of word x correspond to bits 00 to 15
of the device variable given on the left.
•
Bits 00 to 15 of word x +1 correspond to bits 16 to
31 of the device variable given on the left.
•
Bits 00 to 15 of word x +2 correspond to bits 32 to
47 of the device variable given on the left.
•
Bits 00 to 15 of word x+3 correspond to bits 48 to
63 of the device variable given on the left.
•
Bits 00 to 15 of word x+4 correspond to bits 64 to
79 of the device variable given on the left.
•
Bits 00 to 15 of word x+5 correspond to bits 80 to
95 of the device variable given on the left.
•
Bits 00 to 15 of word x+6 correspond to bits 96 to
111 of the device variable given on the left.
•
Bits 00 to 15 of word x+7 correspond to bits 112
to 127 of the device variable given on the left.
•
Bits 00 to 15 of word x+8 correspond to bits 128
to 143 of the device variable given on the left.
•
Bits 00 to 15 of word x+9 correspond to bits 144
to 159 of the device variable given on the left.
•
Bits 00 to 15 of word x+10 correspond to bits 160
to 175 of the device variable given on the left.
•
Bits 00 to 15 of word x+11 correspond to bits 176
to 191 of the device variable given on the left.
•
Bits 00 to 15 of word x+12 correspond to bits 192
to 207 of the device variable given on the left.
•
Bits 00 to 15 of word x+13 correspond to bits 208
to 223 of the device variable given on the left.
•
Bits 00 to 15 of word x+14 correspond to bits 224
to 239 of the device variable given on the left.
•
Bits 00 to 15 of word x+15 correspond to bits 240
to 255 of the device variable given on the left.
Summary of Contents for SYSMAC CJ1W-EIP21
Page 8: ...Manual Structure 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 42: ...Revision History 40 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 68: ...1 Introduction 1 26 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 266: ...9 FTP Server 9 20 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 431: ...Index 1 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 I Index...
Page 436: ...Index 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 Index...
Page 437: ......