7-25
7 Tag Data Link Functions
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
7
-2
Se
tti
n
g T
a
g D
a
ta
Li
n
k
s
7
7-2
-4 Creating T
ags and T
ag Sets
Changing and Registering Tag Sets
11
The following dialog box is displayed when the tags in the Edit Tags Dialog Box are registered
directly as tag sets.
12
If an input tag is already registered in an input tag set, and you want to change its registration to
a different input tag set, it is necessary to delete the tag from the tag set in which it was origi-
nally registered. Open the Edit Device Parameters Dialog Box, select the tag set containing the
tag that you want to delete on the Tag Sets Tab Page, and click the
Delete
Button in the Edit
Tags Dialog Box. (If there are other tags registered in that tag set, it is possible to delete just one
tag by selecting the tag that you want to delete in the Edit Tag Set Dialog Box and clicking the
Button.)
Summary of Contents for SYSMAC CJ1W-EIP21
Page 8: ...Manual Structure 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 42: ...Revision History 40 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 68: ...1 Introduction 1 26 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 266: ...9 FTP Server 9 20 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 431: ...Index 1 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 I Index...
Page 436: ...Index 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 Index...
Page 437: ......