7 Tag Data Link Functions
7-24
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
9
After you register all of the required tags, click the
OK
Button in the Edit Tags Dialog Box.
Precautions for Correct Use
Precautions for Correct Use
Make the following settings to refresh all of the tag data in the same tag set at the same time.
•
Use the Sysmac Studio to specify the same refreshing task for all of the variables that are
assigned to tags in the tag set.
•
Do not place tag variables that have AT specifications in I/O memory and tag variables that do
not have AT specifications in the same tag set.
10
At this point, a confirmation dialog box is displayed to check whether the registered tag names
are used as the tag set names. A tag set can contain up to eight tags, but tag sets are registered
with one tag per tag set if the tag names are registered as tag set names. In this case, click the
Yes
Button.
If the
No
Button is clicked, you can add more tags to the tag set. Refer to step 18 for details on
how to register new tags first and add more tags to the tag set later.
Summary of Contents for SYSMAC CJ1W-EIP21
Page 8: ...Manual Structure 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 42: ...Revision History 40 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 68: ...1 Introduction 1 26 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 266: ...9 FTP Server 9 20 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 431: ...Index 1 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 I Index...
Page 436: ...Index 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 Index...
Page 437: ......