11-9
11 SNMP Agent
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
11-1 SNMP Ag
ent
11
11-1-4
MIB
S
p
e
c
ifications
ipOutNoRoutes
(12) RO
The number of IP datagrams that were discarded
because there was no transmission path. This
counter includes datagrams that attempted to be
sent through ipForwDatagrams, but were dis-
carded because they were set with no-route. This
value indicates the number of datagrams that
could not be transferred because the default gate-
way was down.
Sup-
ported.
According to the
standard.
ipReasmTimeout
(13) RO
The maximum number of seconds to wait to
receive all IP datagrams for reassembly if a frag-
mented IP datagram is received.
Sup-
ported.
60 s
ipReasmReqds
(14) RO
The number of IP datagrams received that require
reassembly. There is a flag in the IP header that
indicates if the datagram is fragmented. You can
use that flag to identify fragments.
Sup-
ported.
According to the
standard.
ipReasmOKs
(15) RO
The number of IP datagrams received that were
successfully reassembled.
Sup-
ported.
According to the
standard.
ipReasmFails
(16) RO
The number of IP datagrams received that were
not successfully reassembled.
Sup-
ported.
According to the
standard.
ipFragOKs
(17) RO
The number of IP datagrams that were success-
fully fragmented.
Sup-
ported.
According to the
standard.
ipFragFails
(18) RO
The number of IP datagrams that were not suc-
cessfully fragmented. (For example, because the
Don’t Fragment flag was set for the IP datagram.)
Sup-
ported.
According to the
standard.
ipFragCreates
(19) RO
The number of IP datagrams created as a result of
fragmentation.
Sup-
ported.
According to the
standard.
ipAddrTable
(20) NA
An address information table for IP addresses.
---
---
Subtree name
Standard [(
identifier
)
attribute
]
Sup-
port
Implementation
specifications
Summary of Contents for SYSMAC CJ1W-EIP21
Page 8: ...Manual Structure 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 42: ...Revision History 40 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 68: ...1 Introduction 1 26 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 266: ...9 FTP Server 9 20 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495...
Page 431: ...Index 1 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 I Index...
Page 436: ...Index 6 CJ series EtherNet IP Units Operation Manual for NJ series CPU Unit W495 Index...
Page 437: ......