7 Tag Data Link Functions
7-30
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
After you import the variables to the tags, click the
Yes
Button to automatically create tag sets,
or click the
No
Button to set up tag sets manually.
The variables will be imported as shown below on the Tag Sets Tab Page. Each variable will be
imported into a different tag set and the device parameters will be automatically edited. (The
variable name will be used for the tag set name.)
To place more than one input variable (input tag) imported from the Sysmac Studio into one tag
set, you must delete the input tags that were registered. Select the tag set containing the vari-
ables you want to put into a tag set, then click the
Delete
Button. A confirmation dialog box is
displayed to confirm that you want to delete the selected tag set and the tags contained in that
tag set. You only want to delete the tag set, so click the
No
Button.