![background image](http://html.mh-extra.com/html/omron/sysmac-c200h-ct001-v1/sysmac-c200h-ct001-v1_operation-manual_742017092.webp)
78
Program
25313 Normally ON.
MOV (21)
#1000
111
MOV (21)
MOV (21)
MOV (21)
MOV (21)
#0003
DM 0000
#0000
DM 0001
#0010
DM 0002
#0000
DM 0003
11400
TIM000
TIM001
TIM
000
TIM
001
11003
MULL (56)
DM 0000
116
DM 0004
DIVL (57)
DM 0004
DM 0004
DM 0002
1101
Sets the sampling time to 1,000 ms.
Inputs 0000 and 0003 to
DM 0000 and DM 0001, respec-
tively.
Inputs 0000 and 0010 to
DM 0002 and DM 0003, respec-
tively.
Turn the internal IN1 signal ON and
OFF every 3 seconds.
Multiplies the counter value by 0.3
when the counting flag turns OFF
and stores the results in DM 0004
and DM 0005.
Gate, Latch, and Sampling Modes
Section 4-4