9
This switch must be set before the Counter Unit is mounted. It is not neces-
sary to set all the pins for all operating modes. Refer to 3-2 Input Selection
and Section 4 Data Allocation and Operating Modes for operational details.
1
2
3
Input type
OFF OFF OFF
OFF OFF
OFF
OFF
ON
ON
ON
ON
ON
*
*
*
Normal
x2
x4
Up and down pulses
Pulse and direction
Offset phases
1
2
3
4
5
6
7
8
ON
Input Selection
Pins 1 through 3 are used to select the type
of inputs for inputs A and B.
4
5
Function
OFF
ON
ON
ON
Input Z effective on falling edge.
Input Z effective on rising edge.
OFF
Input Z inoperative
*
For Operating Mode 1 or 2: Input Z
6
7
Function
OFF
ON
ON
ON
Control input IN1 effective on
falling edge.
Control input IN1 effective on
rising edge.
OFF
Control input IN1 inoperative
*
This setting is effective only for operating
modes 1,2, and 3.
In modes 4, 5, and 6, control inputs IN1 and IN2
are always effective on their rising edges
8
Function
ON
Reset bit effective on rising edge.
OFF Reset bit inoperative
This setting is effective only for operating
modes 1,2, and 3.
Control Input IN1
Internal Reset Bit
4
5
Function
*
ON
Start on control input IN2.
OFF
Start on START command
(IR n, bit 00).
*
For Operating Mode 3: Start Input
*Pins marked with asterisks are not used.
Back Panel DIP Switch
Switch Settings
Section 2-1
Summary of Contents for SYSMAC C200H-CT001-V1
Page 1: ...Cat No W141 E1 4 High speed Counter Units SYSMAC C200H CT001 V1 CT002 OPERATION MANUAL...
Page 2: ......
Page 3: ...C200H CT001 V1 CT002 High speed Counter Units Operation Manual Revised September 2000...
Page 4: ...iv...
Page 6: ...vi...
Page 8: ......
Page 10: ......
Page 20: ......
Page 46: ......
Page 96: ......
Page 98: ......