Switch Settings
Always turn off the Counter Unit before setting the unit number and mode selec-
tors. Use a regular screwdriver, being careful not to damage the slot in the screw.
Be sure not to leave a selector midway between settings.
Switch name
Function
Unit no.
Used to set the unit number. Unit numbers run from 0 through
9 and are the same for all Special I/O Units, i.e. unit number 0
may be assigned to a Position Control Unit; unit number 1, to
a High-speed Counter Unit; etc. Do not set the same number
for more than one Special I/O Unit.
Mode
Used to set the operating mode. Modes run from 1 through 6,
as follows:
1: Linear 2: Circular 3: Preset
4: Gate 5: Latch 6: Sampling
Front Panel DIP Switch
Switch Settings
Section 2-1