IR Area Allocations
Appendix C
90
Preset Operating Mode
Word
Bit
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
#7
#6
#5
#4
#3
#2
#1
#0
Output
n
Output force bits
ENABLE FORCED OUTPUT
RESET
COUNTER
READ ERROR
CHANGE PRESET
---
ENABLE FORCED OUTPUT
TRANSFER DA
T
A
ST
AR
T
n+1
Range enable bits
n+2
TRANSFER DATA beginning channel number
n+3
Number of transfers
TRANSFER DATA data area
#7
#6
#5
#4
#3
#2
#1
#0
Input
n+4
Output flags
Reset flag
Count overflow flag
Error flag
T
ransfer completed flag
---
IN1 flag
---
Counting flag
n+5
Error code
Error location
n+6
Current counter value, 7 digits
n+7
n+8
Range flags
---
Gate, Latch, and Sampling Operating Modes
Word
Bit
15
06
05
04
03
02
01
00
Output
n
---
READ ERROR
Internal IN2
Internal IN1
---
Internal IN1
---
n+1
Sampling time
Input
n+4
---
Count overflow flag
Error flag
---
IN2 flag
IN1 flag
---
Counting flag
n+5
Error code
Error location
n+6
Current counter value (rightmost 4 digits)
n+7
Current counter value (sign and leftmost 3 digits)
Summary of Contents for SYSMAC C200H-CT001-V1
Page 1: ...Cat No W141 E1 4 High speed Counter Units SYSMAC C200H CT001 V1 CT002 OPERATION MANUAL...
Page 2: ......
Page 3: ...C200H CT001 V1 CT002 High speed Counter Units Operation Manual Revised September 2000...
Page 4: ...iv...
Page 6: ...vi...
Page 8: ......
Page 10: ......
Page 20: ......
Page 46: ......
Page 96: ......
Page 98: ......