55
Functions of Digital I/O Units
Section 4-4
4-4-5
Total ON Time Monitor
Function Overview
The total ON time for each I/O contact can be calculated (unit: s) and
recorded in the Unit. A monitor value can be set in the Unit, and when the total
I/O contact ON time reaches the monitor value, the Connected Device Mainte-
nance Flag in the Status Area is turned ON. (Bit 2 of the Communications
Unit’s Status Flags is turned ON.) The Programming Device can be used to
read the status of the Connected Device Maintenance Flag.
• Measured time: 0 to 4,294,967,295 s (stored data: 00000000 to
FFFFFFFF hex)
• Measuring unit: s
Note
1.
The Total ON Time Monitor and Contact Operation Counter cannot be
used at the same time for a single contact. Select the function to be used
in the
Detection Mode
Area.
2.
The Total ON Time Monitor operates when the I/O power is ON only.
3.
The Total ON Time Monitor checks approximately every second whether
the connected devices are ON.
If the total ON time is calculated for ON times of less than a second, the
measurement may not be accurate.
■
Measurement for ON Time of 0.5 s:
In
Figure 1
, the actual ON time is 0.5 s × 3 = 1.5 s. The measurement will be
taken once during this ON time, so the total ON time will be measured as 1 s.
Figure 1
ON
OFF
Total ON time
Recorded in
the Unit
Connected
device
Total ON time
Connected
device
Slice I/O Unit
ON
OFF
Reading taken approximately every second.
0.5 s
Summary of Contents for SmartSlice GRT1-Series
Page 1: ...Slice I O Units Cat No W455 E1 06 SmartSlice GRT1 Series OPERATION MANUAL ...
Page 2: ...SmartSlice GRT1 Series Slice I O Units Operation Manual Revised November 2007 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 13: ...xiv ...
Page 21: ...xxii EC Directives 6 ...
Page 63: ...42 Connecting Turnback Cables Section 3 3 ...
Page 109: ...88 Digital I O Units Section 4 6 ...
Page 251: ...230 Maintenance Information Window Section 7 3 Maintenance Information Window ...
Page 293: ...272 GRT1 CP1 L Positioning Unit Section 7 5 ...
Page 301: ...280 GRT1 END End Unit Section 8 5 Dimensions 11 9 11 9 55 7 1 5 19 5 83 5 2 9 2 9 OMRON ...
Page 323: ...302 Troubleshooting by Unit Section 9 5 ...
Page 351: ...330 Explicit Messages Appendix A ...
Page 355: ...334 Power Consumption and Weight Tables Appendix C ...
Page 357: ...336 I O Current Consumption Table Appendix D ...
Page 365: ...344 Revision History ...