
311
Explicit Messages
Appendix A
Setting Hold/Clear for Communications Errors (Output)
Note
(1) The default setting is for all outputs to be cleared (0).
(2) Bit numbers correspond to output numbers, e.g., bit 00 corresponds to output 0.
Writing Maintenance Information
Explicit Messages for Analog Slaves
Setting and Reading for Analog Input Units
Explicit
message
Read/
write
Function Command
Response
Service
code
Class
ID
Instance
ID
Attribute
ID
Data size
Setting for
Output Sta-
tus (Hold or
Clear) after
Slice Bus
Error
*1
Read
Reads whether
each output’s sta-
tus will be cleared or
held when there is a
slice bus error.
0E hex
8E hex
01 to 40
hex
83 hex
---
4 bytes
Status of bits 00 to
32.
*2
0: Clear
1: Hold
Write
Sets whether each
output’s status will
be cleared or held
when there is a slice
bus error.
10 hex
8E hex
01 to 40
hex
83 hex
4 bytes
Settings for
bits 00 to 32
*2
0: Clear
1: Hold
---
Setting for
Output Sta-
tus (Hold or
Clear) after
Host Net-
work Com-
munications
Error
*1
Read
Reads whether
each output’s sta-
tus will be cleared or
held when there is a
host network com-
munications error.
0E hex
8E hex
01 to 40
hex
84 hex
---
4 bytes
Status of bits 00 to
32.
*2
0: Clear
1: Hold
Write
Sets whether each
output’s status will
be cleared or held
when there is a host
network communi-
cations error.
10 hex
8E hex
01 to 40
hex
84 hex
4 bytes
Settings for
bits 00 to
32.
*2
0: Clear
1: Hold
---
Explicit
message
Read/
write
Function Command
Response
Service
code
Class
ID
Instance
ID
Attribute
ID
Data size
Mainte-
nance
Counter
Save
Save
Records the mainte-
nance counter in the
Slice I/O Unit's
memory.
16 hex
8D hex
01 to 40
hex
*1
71 hex
--
---
Explicit
message
Read
/write
Function Command
Response
Service
code
Class
ID
Instance
ID
Attribute ID
Data
Analog
Data 1
Value
Read Reads the value for
Analog Data 1.
0E hex
8F hex
01 to 40
hex
*1
65 hex
*2
8D hex
*3
2 byte
Analog
Data 2
Value
Read Reads the value for
Analog Data 2.
0E hex
8F hex 01 to 40
hex
*1
68 hex
*2
90 hex
*3
2 bytes
Summary of Contents for SmartSlice GRT1-Series
Page 1: ...Slice I O Units Cat No W455 E1 06 SmartSlice GRT1 Series OPERATION MANUAL ...
Page 2: ...SmartSlice GRT1 Series Slice I O Units Operation Manual Revised November 2007 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 13: ...xiv ...
Page 21: ...xxii EC Directives 6 ...
Page 63: ...42 Connecting Turnback Cables Section 3 3 ...
Page 109: ...88 Digital I O Units Section 4 6 ...
Page 251: ...230 Maintenance Information Window Section 7 3 Maintenance Information Window ...
Page 293: ...272 GRT1 CP1 L Positioning Unit Section 7 5 ...
Page 301: ...280 GRT1 END End Unit Section 8 5 Dimensions 11 9 11 9 55 7 1 5 19 5 83 5 2 9 2 9 OMRON ...
Page 323: ...302 Troubleshooting by Unit Section 9 5 ...
Page 351: ...330 Explicit Messages Appendix A ...
Page 355: ...334 Power Consumption and Weight Tables Appendix C ...
Page 357: ...336 I O Current Consumption Table Appendix D ...
Page 365: ...344 Revision History ...