46
Power Supply Wiring
Section 3-2
Note
The GRT1-TBL Left Turnback Unit has the same screwless clamping power
supply terminals. Those terminals are wired in the same way as the
DeviceNet Communications Unit’s terminals, just by inserting the power sup-
ply wires.
Supplying I/O Power
The power supply for I/O devices is supplied through the DeviceNet Commu-
nications Unit’s screwless clamping power supply terminals. If pin terminals
are used on the wire ends, the pin terminals can just be inserted to wire the
power.
Note
The GRT1-TBL Left Turnback Unit and GRT1-PD2 I/O Power Supply Unit
have the same screwless clamping power supply terminals. Those terminals
are wired in the same way as the DeviceNet Communications Unit’s terminals,
just by inserting the power supply wires.
Removing Wires
Press the release button above the terminal hole with a slotted precision
screwdriver and pull out the wire.
Use the following screwdriver or an equivalent to remove the wires.
Recommended Screwdriver
These terminals supply power to both
the DeviceNet Communications Unit's
internal circuits and the connected
Slice I/O Units' internal circuits.
Holes for wires
(pin terminals)
Release button
Press the release button with a screwdriver
and pull out the wire (pin terminal).
24 VDC
These terminals supply power to the
external I/O devices connected to the
Slice I/O Units.
Holes for wires
(pin terminals)
Release button
Press the release button with a screwdriver
and pull out the wire (pin terminal).
24 VDC
Model
Maker
SZF1
Phoenix Contact
Slotted precision screwdriver
Release button
Summary of Contents for SMARTSLICE - 04-2008
Page 1: ...DeviceNet Communications Unit Cat No W454 E1 03 SmartSlice GRT1 DRT OPERATION MANUAL ...
Page 2: ...SmartSlice GRT1 DRT DeviceNet Communications Unit Operation Manual Revised April 2008 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 13: ...xiv ...
Page 27: ...8 Basic Operating Procedure Section 1 5 ...
Page 57: ...38 Unit Functions Section 2 3 ...
Page 101: ...82 DeviceNet Explicit Messages Appendix A ...
Page 113: ...94 Standard Models Appendix C ...
Page 115: ...96 Power Consumption Tables Appendix D ...
Page 117: ...98 I O Current Consumption Appendix E ...
Page 119: ...100 Glossary ...