![background image](http://html1.mh-extra.com/html/omron/r88a-mcw151-drt-e/r88a-mcw151-drt-e_operation-manual_742243256.webp)
241
Device Protocol (MCW151-DRT-E only)
Appendix B
Item
Section
Information
Max. number of instances
Object instance 1
Attribute
Instance type
Explicit Message
1
Production trigger
Cyclic
---
Transport type
Server
Transport class
3
Item
ID content
Get
(read)
Set
(write)
Value
Object instance 1
Attribute
1 State
Yes
No
---
2 Instance type
Yes
No
0000 (hexadecimal)
3 Transport class trigger
Yes
No
83 (hexadecimal)
4 Produced connection ID
Yes
No
---
5 Consumed connection ID
Yes
No
---
6 Initial comm. characteristics
Yes
No
21 (hexadecimal)
7 Produced connection size
Yes
No
00FE (hexadecimal)
8 Consumed connection size
Yes
No
00FE (hexadecimal)
9 Expected packet rate
Yes
Yes
---
12 Watchdog time-out action
Yes
No
01 (hexadecimal)
13 Produced connection path length
Yes
No
0000 (hexadecimal)
14 Produced connection path
Yes
No
---
15 Consumed connection path length Yes
No
0000 (hexadecimal)
16 Consumed connection path
Yes
No
---
17 Production inhibit time
Yes
No
0000 (hexadecimal)
Item
DeviceNet service
Parameter option
Object instance 1
Service
05 Reset
No
0E Get_Attribute_Single
No
10 Set_Attribute_Single
No
Item
Section
Information
Max. number of instances
Object instance 2
Attribute
Instance type
Polled I/O
1
Production trigger
Cyclic
---
Transport type
Server
Transport class
2