![background image](http://html1.mh-extra.com/html/omron/f10-c20/f10-c20_instruction-sheet_741247026.webp)
46
Input Command
@<unit̲number>MC̲<parameter>[CR]
・ Set the value of <unit̲number> to a number between 00 and
31, or XX.
・ Set the following numerical values for <parameter>.
<parameter> can be omitted. If omitted, the value defaults to 1.
Output Response
@<unit̲number>MC̲OK[CR] : Executed correctly
@<unit̲number>MC̲ER[CR] : Not executed correctly
<unit̲number>
Unit number (00 to 31)
Example
To change all connected F10's to external signal line priority mode:
Input: @XXMC̲0[CR]
Output: (No response)
----------------------------------------------------------------------------------------------
■ MD -Measure Data- :Acquire previous measurement results
----------------------------------------------------------------------------------------------
MD returns the previous measurement results. The results are not
output to the external signal line.
Input Command
@<unit̲number>MD[CR]
@<unit̲number>MD̲<parameter>[CR]
・ Set the following numerical values for <unit̲number>.
45
Parameter
0
1
Content
Signal priority mode
Serial priority mode
Unit No.
00 to 31
Content
Unit number of Unit performing measurement.
Unit No.
00 to 31
XX
Content
Unit number of Unit to change.
Used to change all F10's.
・ Set the following numerical values for <unit̲number>.
・ Set the following numerical values for <type>.
・ Set the following numerical values for <level>.
Output Response
@<unit̲number>LS̲OK[CR] : Executed correctly
@<unit̲number>LS̲ER[CR] : Not executed correctly
<unit̲number>
00 to 31: Designated unit number
Example
To change the pattern measurement threshold levels of all connected
F10's to 6:
Input :@XXLS̲2̲6[CR]
Output : (No response)
----------------------------------------------------------------------------------------------
■ MC -Mode Change-
:Change mode priority between
external signal line and serial communications
----------------------------------------------------------------------------------------------
MC enables changing the mode of an F10 amplifier to external signal
line priority mode even when its DIP switch is set to serial
communications priority mode. After using MC to change to external
signal line priority mode, all other commands will be ignored until the
mode is returned to serial communications priority mode.
Type
0
1
2
3
Content
Contrast threshold (plain measurement)
Concentration mean threshold (plain measurement)
Agreement level threshold (pattern measurement)
Measured item selection (pattern/plain) level threshold
Type
1 to 7
Content
Threshold level
Unit No.
00 to 31
XX
Content
Unit number of the Unit whose threshold level is to be set.
Used when setting all F10 threshold levels.