![background image](http://html1.mh-extra.com/html/omron/f10-c20/f10-c20_instruction-sheet_741247024.webp)
42
When this command is recognized, a READY response will be returned.
After verifying that this response has been received, the host must
transfer the bank data using the XMODEM (-CRC or ミSUM) protocol.
When the transfer of all data has been completed, a response indicating
normal completion will be returned.
Example
To transfer data to the current bank in Unit 7:
Input :@07BL̲CU[CR]
Output :@07BL̲READY[CR]
(Transfer data using XMODEM.)
Output :@07BL̲OK[CR]
----------------------------------------------------------------------------------------------
■ BS -Bank data Save- : Transfer bank data to external device
----------------------------------------------------------------------------------------------
When this command is recognized, the bank data is transferred by
XMODEM (-CRC or -SUM) protocol.
"Bank data" is setting data that does not include system data.
Input Command
@<unit̲number>BS̲<parameter>[CR]
・ Set the following numerical values for <unit̲number>.
・ Set the following numerical values for <parameter>.
Output Response
@<unit̲number>BS̲OK[CR] :Data transfer completed normally
@<unit̲number>BS̲ER[CR] :Data transfer not completed
normally
<unit̲number>00 to 31 :Unit number of Unit transferring data
・The response is returned after transfer has been completed.
41
・ Set the following numerical values for <bank̲number>.
Output Response
@<unit̲number>BC OK[CR] : Executed correctly
@<unit̲number>BC ER[CR] : Not executed correctly
<unit̲number>
00 to 31: Unit number of Unit to change
Example
To change the bank number of Unit 10 to 7:
Input: @10BC̲07[CR]
Output: @10BC̲OK[CR]
----------------------------------------------------------------------------------------------
■ BL -Bank data Load- : Transfer bank data from an external device.
----------------------------------------------------------------------------------------------
Use the XMODEM (-CRC or ミSUM) protocol for data transfers.
"Bank data" is setting data that does not include system data.
Input Command
@<unit̲number>BL̲<parameter>[CR]
・ Set the following numerical values for <unit̲number>.
・ Set the following numerical values for <parameter>.
Output Response
@<unit̲number>BL̲READY[CR] :Transfer preparations
completed
@<unit̲number>BL̲OK[CR] :Transfer concluded normally
@<unit̲number>BL̲ER[CR] :Command not executed
correctly
<unit̲number>00 to 31: Unit number of Unit whose data is
to be transferred
Unit No.
00 to 31
Content
Unit number whose bank data is to be transferred.
Parameter
AL
CU
00 to 07
Content
Transfer all bank data.
Transfer data from current bank.
Transfer data from specified bank number.
Unit No.
00 to 31
Content
Unit number whose bank data is to be transferred.
Parameter
AL
CU
00 to 07
Content
Transfer all bank data.
Transfer data to current bank.
Transfer data to specified bank number.
Bank No.
00 to 07
Content
Bank number
形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 41