Specifications/Functions
Item
Operating temperature
Operating humidity
Storage temperature
Operating environment
Input power supply
Current consumption
Insulation resistance
Dielectric strength
Degree of protection
Vibration resistance
Shock resistance
F10-C20 / C25 / C30 / C35 / C50 / C55
0 ℃ to 50 ℃
35 % to 85 % RH (with no condensation)
-25 ℃ to 65 ℃ (with no icing)
With no corrosive gas
+21.6 to 26.4 V DC (with ripple (p-p) 10%)
300 mA max.
20 M ohm min. (at 500 V DC)
1,000 V AC at 50 / 60 Hz 1 min
IEC60529 IP40
10 to 150 Hz, 0.75-mm max. single amplitude or 100
m/s
2
-max. for 32 min each in X, Y, and Z directions
Peak acceleration : 300 m/s
2
3 times each in X, Y, and Z directions
Cord length
2 m
Casing material
ABS
Weight
Approx. 300 g with pack case (only Amplifier with cable : approx. 200 g)
Appurtenance
Instruction sheet (this manual)
●General Specifications
Item
Measurement item
Automatic teaching function
Storage temperature
Model size
Measurement processing time
Number of registered models
bank switching
Output switching
Output off-delay
function
F10-C20 / C25
Pattern measurement
Yes
−25 to 65℃(with no icing and condensation)
Normal or wide (selectable)
3.6 ms in normal wide and 10.8 ms in wide mode (continuous measurement)
1 model
1 bank
Concord output : Output turns ON, if being concordant with registered model
Discord output : Output turns ON, if not being concordant with registered model
20 ms, 40 ms (default), 60 ms, 80 ms, 100 ms, 120 ms,
140 ms, 160 ms
1 model per 1 bank
8 banks
F10-C30/C35/C50/C55
●Performance Specifications
Head interface (1 channel)
Available Head : F10-S30R, or F10-S15R, or F10-
Item
Teaching button
Select button
Mode selector
Auto-teaching selector
Model size selector
Off-delay timer selector
Concord or discord output selector
F10−C20/C25/C30/C35
Yes
UP/DOWN
TEACH/MON/RUN
OFF/ON
NORMAL / WIDE
Timer ON / OFF
Concord / Discord
External input selector
No
LINE/RS-232C・422
F10−C50/C55
●Operation Interface
Item
Control output
Enable output
External trigger input (with minimum pulse width of 1 ms)
Continuous measurement
Moving object teaching input
Stationary object teaching input
bank switching input
F10−C20/C25/C30/C35
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
F10−C50/C55
●External I/O Interface
Item
Load voltage
Residual voltage
NPN open collector output type
F10-C20 / C30 / C50
30 V max.
1.2 V max.
2.0 V max.
Load current
50 mA max.
PNP open collector output type
F10-C25 / C35 / C55
・External Output Specifications
Line
Output
Line
Input
S05R, or F10-S15R