60
59
10.
Dimensions
25
6
55
20.5
19.5
5.7-dia. 11-core vinyi-insulated round cable, standard length :
2m
(C
onductor cross-section
:
0.2mm
2
, Insulator diameter
φ
1.0mm
)
.
35.2
30
21
30.8
80
89
98
21
2-M4
RS-232C/422
(F10-C50/C55 only)
Connect to Head
89
・
Mounting Dimensions
Teaching data setting er-
ror
The Sensor was set to
MONITOR or RUN mode
before teaching comple-
ted.
A current exceeding the rated val-
ue has flowed to the output transis-
tor and the over-current protective
circuit has been triggered.
Reduce the current so
that it will not exceed
the rated value.
Consult your OMRON
representative, when
these signals do not be-
come ON even if reduc-
ing.
・The F10-S30R/S50R can not detect red object with white backgrounds.
Use the F10-S15R/S05R inseead.
・The F10-S15R/S05R can not detect green object with white backgrounds.
Use the F10-S30R/S50R inseead.
Perform the teaching
of the Sensor in
TEACH mode.
All the LED of
the threshold
indicators fla-
shes and the
buzzer sounds.
Serial buffer overflow er-
ror
Either the send buffer or
receive buffer has be-
come full during commu-
nications.
Send buffer overflow Change
the communications settings.
Receive buffer overflow
Wait for a response from the
F10 then send the command.
This LED of
the threshold
indicators fla-
shes and the
buzzer sounds.
Control output (OUTPUT)
and enable output are OFF,
and will not turn ON.
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
Refer to 1.Pattern
Registration(TEACH
Mode)on page 19.
Buzzer
sounds
Buzzer
sounds
Problem
Probable cause
Remedy
This LED of
the threshold
indicators fla-
shes and the
buzzer sounds
three times.
8
7
6
5
4
3
2
1
Buzzer
sounds
Detection Range type error
Detection Range mode
currently set is different
from that set in teaching.
Perform again the teaching
in TEACH mode or change
the Detection Range mode.
Refer to
4.1.
TEACH mode.
形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 59