・ Set the following numerical values for <type>
Output Response
@<unit̲number>LG̲<level>[CR] :Executed correctly
@<unit̲number>LG̲ER[CR]
:Not executed correctly
<unit̲number>
00 to 31: Designated unit number
<level>
1 to 7: Threshold level
Example
To acquire the threshold level of the Pattern Measurement Mode of
Unit 5:
Input: @05LG̲2[CR]
Output: @05LG̲4[CR] (when threshold level is 4)
----------------------------------------------------------------------------------------------
■ LS -Level Set-
: Set threshold level
----------------------------------------------------------------------------------------------
LS sets the threshold level. Any of the four threshold levels can be set
regardless of the current measurement mode.
Input Command
@<unit̲number>LS̲<type>̲<level>[CR]
43
1.Threshold level
8
7
6
5
4
3
2
1
7.Threshold level
Type
0
1
2
3
Content
Contrast threshold(plain measurement)
Concentration mean threshold (plain measurement)
Agreement level threshold(pattern measurement)
Measured item selection (pattern/plain) level threshold
Example
To transfer all bank data from Unit 6 to the host:
Input :@06BS̲AL[CR]
(Data will be transferred using the XMODEM protocol.)
Output :@06BS̲OK[CR]
----------------------------------------------------------------------------------------------
■ HT -Head Type-
:Acquire head type
----------------------------------------------------------------------------------------------
HT acquires the head type.
Input Command
@<unit̲number>HT[CR]
・ Set the following numerical values for <unit̲number>.
Output Response
@<unit̲number>HT̲<type>[CR] :Executed correctly
<unit̲number>
00 to 31:Designated unit number
<type>
S30R:F10-S30R
S15R:F10-S15R
S05R:F10-S05R
Example
To acquire the head type of Unit 30:
Input: @30HT[CR]
Output: @30HT̲S15R[CR] (when F10-S15R is connected)
----------------------------------------------------------------------------------------------
■ LG -Level Get-
: Acquire threshold level
----------------------------------------------------------------------------------------------
LG acquires the threshold level. Four threshold levels are retained in
memory, regardless of the current measurement mode. The specified
level will be returned.
Input Command
@<unit̲number>LG̲<type>[CR]
・ Set the following numerical values for <unit̲number>.
Unit No.
00 to 31
Content
Unit number of the Unit whose head type is to be acquired.
Unit No.
00 to 31
Content
Unit number of Unit whose threshold level is to be acquired.