![background image](http://html1.mh-extra.com/html/omron/f10-c20/f10-c20_instruction-sheet_741247031.webp)
56
@<unit̲number>SS̲ER[CR] : Not executed correctly
<unit̲number> 00 to 31: Unit number of Unit to set
After the baud rate has been changed, output will remain at the previous
baud rate until a response output has been returned.
Example
To change the unit number from 24 to 3:
Input: @24SS̲0̲03[CR]
Output: @24SS̲OK[CR] (Unit number will change to 3 after this response.)
----------------------------------------------------------------------------------------------
■TC-TeaCh-
:Execute teaching
----------------------------------------------------------------------------------------------
Input Command
@<unit̲number>TC̲<type>̲<A.T.OFF/ON>̲<pattern/plain>̲
<normal/wide>[CR]
・ Set the following numerical values for <unit̲number>.
・ Set the following numerical values for <type>.
・Stationary Object Teaching is accomplished with this single
command. There is no need to turn CONT or TRIG ON. During
teaching the ENAB signal will be ON.
55
number for <parameter> cannot be specified.
・ Set the following numerical values for <parameter> and <value>.
After changing the unit number, the previous unit number will
remain in effect until a response output has been returned
Output Response
@<unit̲number>SS̲OK[CR] : Executed correctly
Normal/Wide
0
1
Content
Set in Normal Mode
Set in Wide Mode.
Unit No.
00 to 31
XX
Content
Unit number of Unit on which to perform teaching.
Used to perform teaching on all F10's.
Type
0
1
2
Content
Stationary Object Teaching
Moving Object Teaching (start)
Moving Object Teaching (abort)
A.T.OFF/ON
0
1
Content
Auto Teach OFF
Auto Teach ON
Pattern/Plain
0
1
Content
Set in Pattern Measurement Mode
Determine whether to use Pattern or Plain Measurement Mode, then set.