![background image](http://html1.mh-extra.com/html/omron/f10-c20/f10-c20_instruction-sheet_741247003.webp)
Table of Contents
1.
Specifications/Functions ……………………………1
2.
Components …………………………………………4
3.
I/O Circuit Diagram ………………………………11
4.
Connection of Serial Communication ……………16
5.
Setting Procedure
(All model : Pattern measurement only)
…19
5.1
TEACH Mode……………………………………19
5.2
MONITOR Mode ………………………………24
5.3
RUN Mode ………………………………………27
6.
External Teaching in RUN Mode …………………31
6.1
Stationary Object Teaching(S̲TEACH)……31
6. 2
Moving Object Teaching(M̲TEACH)………32
7.
System setting ………………………………………33
7.1
Off-delay timer setting …………………………33
7.2
Unit Number setting(only F10-C50/C55) ……34
7.3
Serial Communication's Baud Rate setting ……35
(only F10-C50/C55)
7.4
Mode Change Plain Measurement Process …36
8.
Serial Communication Command
(only F10-C50/C55)
…37
8.1
Input Format ……………………………………37
8.2
Output Format …………………………………38
8.3
List of Input Commands ………………………39
8.4
Command Reference ……………………………40
9.
Trouble Shooting……………………………………58
10.
Dimensions …………………………………………60
forced-air cooling fan or the air-conditioner to keep the
temperature under 50 ℃.
3. Noise Resistance
・ Do not wire power lines or high-tension lines alongside lines of
the Sensor in the same conduit, otherwise the Sensor may be
damaged or malfunction due to induction. Be sure to wire the lines
of the Sensor separately from power lines or high-tension lines or
within an exclusive, shielded conduit.
・If power lines with high current for motors are wired close to the
Amplifier, make sure that the Amplifier operates normally and take
proper measures so that the power lines will not have a bad
influence on the operation of the Amplifier.
・If a standard switching regulator is connected to the Sensor, be
sure to ground the FG (frame ground) and G (ground) terminals
of the switching regulator. The Sensor may malfunction due to
switching noise that will be generated from the switching
regulator if these terminals are not grounded.
・An extension cord of the Amplifier can be used provided that the
thickness and length of the wire are 0.3 mm
2
min. and 20 m max.
respectively.
・Do not bring the connector on the Amplifier and the metal screws
on the bottom of the Amplifier into contact with other metals,
because the connector and the bottom-metal- screws of the
Amplifier are connected internally to 0-V terminal of the Amplifier.
4. Maintenance
・Organic solvents may damage the casing of the Amplifier, which is
made of ABS resin. Do not use any other organic solvent (paint
thinner, benzine or alcohol etc.) to clean the product.
5. Others
・The Sensor is ready to operate within 1 sec after the Sensor is
turned on. If the Sensor and load are connected to separate power
supplies, be sure to turn on the Sensor first.
・Do not disconnect or connect the Head while the Sensor is turned
ON.