8.4 Command Reference
Command formats are explained below in alphabetical order.
Commands are input in ASCII. Only uppercase characters can be used.
The space character ($20) displays as "̲" (under-bar) in this command
reference.
----------------------------------------------------------------------------------------------
■ BA -BAnk-
: Acquire current bank number
----------------------------------------------------------------------------------------------
BA acquires the current bank.
Input Command
@<unit̲number>BA[CR]
・ Set the following numerical values for <unit̲number>.
Output Response
@<unit̲number>BA̲<bank̲number>[CR]:Executed correctly
<unit̲number>
00 to 31: Unit number of Unit to
acquire bank number
<bank̲number>
00 to 07: Bank number
Example
To acquire the current bank in Unit 0 (when the bank number is 1):
Input: @00BA[CR]
Output: @00BA̲01[CR]
----------------------------------------------------------------------------------------------
■ BC -Bank Change-
: Change bank number
----------------------------------------------------------------------------------------------
BC changes the bank number to a specified bank number.
Input Command
@<unit̲number>BC̲<bank̲number>[CR]
・ Set the following numerical values for <unit̲number>.
39
Unit No.
00 to 31
Content
Unit number of the Unit whose bank number is sought.
Unit No.
00 to 31
Content
Unit number of the Unit whose bank number is sought.
8.3 List of Input Commands
■ Specifying F10 Operation
The following commands specify the operation of the F10, such as executing a
measurement, changing the bank number, etc.
■ Saving/Loading data
The following commands back up data that has been set using F10.
■ Acquiring or Changing Current Settings
The following commands acquire threshold levels or other setting or change the
settings.The host can use these commands to determine F10 settings, as well
as modify values and specify operation.
Command
BC
MD
ME
RT
TC
Function
Change bank number.
Acquire previous measurement result.
Execute image capture measurement once only.
Begin continuous or synchronous measurements.
Execute measurement of image in image memory once only.
Stop measurement.
Reset.
Execute teaching.
Command
BL
BS
SG
SS
Function
Transfer bank data from external device (load).
Transfer bank data to external device (save).
Acquire system data.
Set system data.
Command
BA
HT
MC
MM
LS
LG
Function
Acquire the current bank number.
Acquire the head type.
Change the signal/serial priority mode.
Acquire the measurement mode.
Set the threshold level.
Acquire the threshold level.