![background image](http://html1.mh-extra.com/html/omron/f10-c20/f10-c20_instruction-sheet_741247012.webp)
18
17
・F10-VR2
RS-232C Cable: D-sub 9-pin connector (2 m)
1
5
6
9
Pin No.
Signal
Name
SD(TXD)
RD(RXD)
SG(GND)
Send data
Receive data
Signal ground
2
3
5
・F10-VR4
RS-422 Cable: D-sub 9-pin connector (2 m)
1
5
6
9
Pin No.
Signal
Name
RDB(+)
SG(GND)
SDB(+)
RDA(−)
SDA(−)
Receive data (+)
Signal ground
Send data (+)
Receive data (-)
Send data (-)
1
3
5
6
9
Note: Signal and name are in reference to the F10.
Note: Signal and name are in reference to the F10.
・Please cover serail-communication-connector with the attached
cap, when not using.
・Please fix surely the cable in order not to take off the connector.
●Multidrop Connections
F10-C50/C55
F10-C50/C55
F10-C50/C55
Link Adapter
Branching Link Adapter
Branching Link Adapter
Branching Link Adapter
F10-VR4
RS-422 Cable
F10-VR4
RS-422 Cable
F10-VR4
RS-422 Cable
Recommended Link Adapters (manufactured by OMRON)
Link Adapter
Branching Link Adapter
B500-AL004
B500-AL001
A maximum of 31 F10-C50/C55 Sensors can communicate with an IBM
PC/AT or compatible by connecting though RS-232C/422 converters.
IBM PC/AT or
compatible
System configuration
Note : Set surely the End of Resistor to "Yes" of the Branching Link Adapter
B500-AL004 and input the resistor to the last link adapter asfollows.
Between RDA(-) and RDB(+) : 220 ohm ( 1/2 W min. )
Between SDA(-) and SDB(+) : 220 ohm ( 1/2 W min. )
形F10-C20/C25/C30/C35/C50/C55 02.11.19 10:12 AM ページ 17