7.2 Unit Number setting
(only F10-C50/C55)
1. Set the mode selector to TEACH, before turning on the power supply.
2. While pressing the Teaching button and SELECT UP button, turn on the pow-
er supply.
3. Release the Teaching and SELECT UP buttons, after lighting on the 2 upper
threshold indicators.
4. The lighting level and bank number indicators display the current unit number
setting. The lighting level indicators display MSD (most significant digit :
101) and the bank number indicators display LSD (LSD; least significant digit:
100).
5. Press the SELECT buttons to adjust the unit number.
6. Press the teaching button, after adjusting the unit-number.
It is possible to change the unit number by the serial communication command
too. Please refer to the 7.4 Command Reference.
Ex.) Unit number : 23
Do not turn off, before pressing the teaching button, otherwise
the changed timer will not be registered.
8
7
6
5
4
3
2
1
Lighting Level Indicator
Level 8
Level 7
Level 6
Level 5
Level 4
Level 3
Level 2
Level 1
Off-delay timer
160ms
140ms
120ms
100ms
80ms
60ms
40ms(default)
20ms
7.1 Off-delay timer setting
1. Set the mode selector to TEACH, before turning on the power supply.
2. While pressing the SELECT UP and Down buttons, turn on the power supply.
3. Release the SELECT UP and DOWN buttons, after lighting on the 3 center
threshold indicators.
4. The lighting level indicator displays the current off-delay timer setting.
5. Press the SELECT buttons to adjust the off-delay timer.
6. Press the teaching button, after adjusting the off-delay timer.
Do not turn off, before pressing the teaching button, otherwise
the changed timer will not be registered.