Lighting Level Indicator
Level 6
Level 5
Level 4
Level 3
Level 2
Level 1
Baud rate
38400bps(Default)
19200bps
9600bps
4800bps
2400bps
1200bps
Item
Data length
Parity
Stop bit
Flow
Settings
8 (bits)
None
1 (bits)
None
7.3 Serial Communicationユ Baud Rate setting
(only F10-C50/C55)
1. Set the mode selector to TEACH, before turning on the power supply.
2. While pressing the Teaching button and SELECT DOWN button, turn on the
power supply.
3. Release the Teaching and SELECT DOWN buttons, after lighting on the 2 low-
er threshold indicators.
4. The lighting level indicators display the current baud rate setting.
5. Press the SELECT buttons to adjust the baud rate.
6. Press the teaching button, after adjusting the baud rate.
Note : The other settings in the communication specifications are fixed as follows.
Do not turn off, before pressing the teaching button, otherwise
the changed timer will not be registered.
It is possible to change the unit number by the serial communication
command too. Please refer to the 7.4 Command Reference.
7.4 Mode Change Plain Measuement Process
1. Change the Mode selector to TEACH, while the power supply is turning off.
2. Turn on the power supply, while pushing the Teach/display button.
3. Release the Teach/display button after confirming that the illumination of each
2 pieces of the upper and the lower side of the Threshold Indicators.
4. The current Plain Measurement detection range selection mode is displayed
to the Level Indicators.
5. Mode can be switched with the UP/DOWN selection buttons.
6. By pushing the Teach/display button after switching it̀ s confirmed.
8
7
6
5
4
2
3
1
Level Indicators that
is lighted
Plain Measurement detection
range selection mode
Level 7,8
Mode 1 (Initial setting)
Level 1,2
Mode 2
Please do not turn off the power supply before pushing the Teach/display
button. The setting is not changed
Plain Measurement detection range selection mode can be confirmed by
processing as following.
1. Switch Mode Selector to MON.
2. Push the Teach/display button for more than 2 seconds.
Plain Measurement detection range selection mode is displayed.
Mode 1
Action is returned to the normal
Monitor mode after Level
Indicators 7 and 8 are lighted
for 3 seconds.
Action is returned to the normal
Monitor mode after Level
Indicators 1 and 2 are lighted for
3 seconds.
8
7
6
5
4
2
3
1
8
7
6
5
4
2
3
1
Mode 2