Bank Change Input
Please input the number of BANK to "BANK 1 to 3" input lines.
The relation of "BANK 1 to 3" and the number of BANK is shown as follows.
ENAB
ON
OFF
OUTPUT
ON
OFF
BANK1
〜
3
OFF
ON
MAX 20ms
BANK No.
BANK Input 1
BANK Input 2
BANK Input 3
BANK 0
BANK 1
BANK 2
BANK 3
BANK 4
BANK 5
BANK 6
BANK 7
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
MAX 60ms
CONT
ON
OFF
During Changing BANK
The both ENAB and OUTPUT are off
while changing BANK.
MAX 30ms
The measurement time depends
on the measurement mode.
MAX 20ms
The BANK Change Input is
ignored while measuring.
Measuring
Measuring
Please restart the measurement process,
after confirming that the ENAB output is
ON.
The measurement is finished, after CONT signal
input is OFF. And then F10 check the status of
other input signals, ex. BANK
Change input.
ON
OFF
Press and hold
down the UP
selection
0.7s max.
ON
OFF
OUTPUT
You can set the guide light to always ON to turn ON the
guide light and execute synchronous measurement.
Press the UP selection button when in RUN mode to turn
ON and OFF the guide light.
While the guide light is being turned ON or OFF, the ENAB
signal is turned OFF, and no external inputs can be
received.
The OUTPUT signal is turned OFF when the UP selection
button is pressed.
ON
OFF
Guide light
ON
OFF
ON
OFF
ENAB
:Lit
:Unit