Example
To acquire the measurement mode of Unit 26:
Input: @26MM[CR]
Output: @26MM̲N[CR] (when unregistered)
----------------------------------------------------------------------------------------------
■ RT -ReseT-
: Reset
------------------------------------------------------------------------------------------------------------------------------------
RT resets the F10. Once RT is recognized, a response is returned and
the reset operation is performed.
Input Command
@<unit̲number>RT[CR]
・ Set the following numerical values for <unit̲number>
Output Response
@<unit̲number>RT̲OK[CR] : Recognized normally
<unit̲number> 00 to 31: Designated unit number.
Example
To reset Unit 21:
Input: @21RT[CR]
Output : @21RT̲OK[CR] (Reset is performed after this
response is transmitted.)
51
Input: @27ME̲4̲1[CR]
Output: @27ME̲READY[CR]
(Measurement performed on image in memory)
Output: 122[CR]
Output: @27ME̲OK[CR]
----------------------------------------------------------------------------------------------
■ MM -Measure Mode-
: Acquire measurement mode
----------------------------------------------------------------------------------------------
MM acquires the current measurement mode.
Input Command
@<unit̲number>MM[CR]
・ Set the following numerical values for <unit̲number>.
Output Response
@<unit̲number>MM̲<measurement̲mode>[CR] :Executed
correctly
<unit̲number>
00 to 31: Designated unit number
<measurement̲mode> 0: Plain Measurement Mode
1: Pattern Measurement Mode,
1 model
2: Pattern Measurement Mode,
2 models, Wide Mode
3: Pattern Measurement Mode,
3 models, Wide Mode
N: Not registered
・If registered in Plain Measurement Mode, 0 is returned regardless of
whether the Unit is in Normal or Wide Mode.
・ In Normal Mode or Wide Mode with single-model Pattern
Measurement Mode,1 is returned.
・In Wide Mode with 2 or 3 models registered, 2 or 3 is returned.
・If unregistered, the response
“N”
is returned.
Unit No.
00 to 31
Content
Unit number of Unit whose data is to be acquired.
Parameter
0
1
2
3
Content
Unit number
Baud rate
OFF delay timer value
LED guide light ON/OFF
Unit No.
00 to 31
XX
Content
Unit number of the Unit to reset.
Used to reset all F10's.
Unit No.
00 to 31
Content
Unit number of the Unit whose measurement mode is to be acquired.