![background image](http://html1.mh-extra.com/html/omron/cx-motion-ncf-v1-9/cx-motion-ncf-v1-9_operation-manual_744182081.webp)
57
Uploading Data
Section 7-4
6.
If the connection was established at Step 2, the connection status can be
restored (released in this case) here. To release the connection, click the
OK
Button. Otherwise, click the
Cancel
Button.
7.
When the Download to NC Unit Dialog Box is closed, the download will be
completed.
Note
When the MECHATROLINK communications cannot be started, Servo
Parameters cannot be downloaded. Start the MECHATROLINK communica-
tions first and download Servo Parameters.
7-4
Uploading Data
The object of uploading varies depending on the operation method.
Batch Uploading
Uploads Unit Parameters and Servo Parameters of all the Servo Drives regis-
tered in the scan list in the Position Control Unit.
Uploading Unit
Parameters
Uploads Unit Parameters.
Uploading Servo
Parameters
Uploads Servo Parameters.
Note
Before starting MECHATROLINK communications, make sure that the PLC is
in the PROGRAM Mode. Otherwise, the axis may start moving suddenly due
to the ladder execution.
Before disconnecting MECHATROLINK communications, make sure that the
axis is not operating. Disconnecting MECHATROLINK communications will
put the operating axis in the Servo Free state.
7-4-1
Batch Uploading
1,2,3...
1.
In the Axis Map Setting Window, select
Online - Upload from NC Unit
,
click
in the toolbar, or right-click the Position Control Unit and select
Upload from NC Unit
from the pop-up menu. The following dialog box will
be displayed.
Summary of Contents for CX-MOTION-NCF - V1.9
Page 1: ...Cat No W436 E1 09 CX Motion NCF Ver 1 9 SYSMAC CXONE AL_C V3 CXONE AL_D V3 OPERATION MANUAL...
Page 2: ......
Page 3: ...CXONE AL C V3 CXONE AL D V3 CX Motion NCF Ver 1 9 Operation Manual Revised September 2009...
Page 4: ...iv...
Page 6: ...vi...
Page 20: ...xx...
Page 24: ...xxiv Application Precautions 5...
Page 36: ...12 Connecting to PLC Section 2 2...
Page 40: ...16 Screen Name Section 3 1 Monitor Windows Axis Monitor Window Unit Monitor Window...
Page 66: ...42 Editing Servo Parameters Section 5 2...
Page 71: ...47 Print Section 6 5 Print Samples An example of printed Unit Parameters is shown below...
Page 92: ...68 Writing to Flash Memory Section 7 6...
Page 106: ...82 Axis Monitor Section 8 2...
Page 112: ...88 Test Run Section 9 1...
Page 138: ...114 Troubleshooting Section 11 3...
Page 142: ...118 Index...
Page 146: ...122 Revision History...