109
Error Codes
Section 11-2
---
---
---
145
---
4091
Regeneration
overload
The regeneration load
exceeded 85% of regenera-
tion overload alarm level.
A.92
A.92
@
---
---
---
4092
This warning occurs before
the Regeneration Overload
Alarm (A.32) occurs. If opera-
tion is continued in this state,
an alarm may occur.
---
---
---
146
---
4092
Battery warning
(Absolute encod-
ers only)
Battery voltage of absolute
encoder decreased to max
about 3.2V (Replace battery
while Control circuit power is
ON).
A.93
A.93
@
---
---
---
4093
This warning occurs before
the Battery Error (A.83)
occurs. If the power is turned
OFF, an alarm may occur the
next time the power is turned
ON. (Replace the battery
while the control circuit power
supply is ON.)
---
---
---
147
---
4093
Fan lock warning Internal cooling fan has
stopped or turned abnormally.
A.94
A.94
@
A.94
148
94
No code
(See note
3.)
Parameter set-
ting warning
A value outside the setting
range has been set for the
MECHATROLINK slave sta-
tion device.
A.95
A.95
@
A.95
149
95
No code
(See note
3.)
MECHA-
TROLINK-II com-
mand warning
An illegal communications
command or unsupported
communications command
has been sent to the MECHA-
TROLINK slave station
device.
A.96
A.96
@
A.96
150
96
4096
Communications
warning
A single MECHATROLINK-II
communications error has
occurred. (See note 4.)
---
---
---
---
A0
40A0
Overload warn-
ing
The load rate exceeded 85%
of the protection level.
---
---
---
---
A1
40A1
Excessive regen-
eration warning
The regeneration load rate
exceeded 85% of the speci-
fied level.
---
---
---
---
A2
40A2
Battery warning
The battery voltage
decreased to 3.2 V or lower.
---
---
---
---
A3
40A3
Fan warning
The fan has stopped for 1
second or longer.
---
---
---
---
A4
40A4
Encoder commu-
nications warning
The number of continuous
occurrences of encoder com-
munications errors exceeded
the specified value.
Servo Drive display
Position
Control
Unit error
code
Warning
detection
function
Warning details
W
Series
W-series
(Built-in
Communi-
cations
Type)
SMART-
STEP
Junior
(Built-in
communi-
cations
Type)
G-Series
(Built-in
communi-
cations
Type)
G5-Series
(Built-in
communi-
cations
Type)
Summary of Contents for CX-MOTION-NCF - V1.9
Page 1: ...Cat No W436 E1 09 CX Motion NCF Ver 1 9 SYSMAC CXONE AL_C V3 CXONE AL_D V3 OPERATION MANUAL...
Page 2: ......
Page 3: ...CXONE AL C V3 CXONE AL D V3 CX Motion NCF Ver 1 9 Operation Manual Revised September 2009...
Page 4: ...iv...
Page 6: ...vi...
Page 20: ...xx...
Page 24: ...xxiv Application Precautions 5...
Page 36: ...12 Connecting to PLC Section 2 2...
Page 40: ...16 Screen Name Section 3 1 Monitor Windows Axis Monitor Window Unit Monitor Window...
Page 66: ...42 Editing Servo Parameters Section 5 2...
Page 71: ...47 Print Section 6 5 Print Samples An example of printed Unit Parameters is shown below...
Page 92: ...68 Writing to Flash Memory Section 7 6...
Page 106: ...82 Axis Monitor Section 8 2...
Page 112: ...88 Test Run Section 9 1...
Page 138: ...114 Troubleshooting Section 11 3...
Page 142: ...118 Index...
Page 146: ...122 Revision History...