![background image](http://html1.mh-extra.com/html/omron/cx-motion-ncf-v1-9/cx-motion-ncf-v1-9_operation-manual_744182124.webp)
100
Error Codes
Section 11-2
---
---
---
13
---
400D
Main power und-
ervoltage
When Undervoltage Alarm
Selection (Pn065) was 1, L1 to
L3 experienced power interrup-
tion that was longer than time
set for Momentary Power Inter-
ruption Hold Time (Pn06D) or
main circuit P to N voltage
decreased under specified
value while Servo was turned
ON.
---
---
---
---
13
@
• The main circuit DC voltage
decreased.
• Disconnection was detected
in the AC power supply of the
main circuit.
---
---
---
14
14
@
400E
Overcurrent Overcurrent
has
occurred.
---
---
---
15
15
@
400F
Servo Drive over-
heat
Servo Drives radiator and
power element overheated
beyond the specified value.
A.10
A.10
@
A.10
---
---
4010
Overcurrent
Overcurrent has occurred or
radiator overheated error was
detected (3 to 15-kW models
only).
---
---
---
16
---
Overload
The effective value of the
torque command exceeded the
overload level that is set for
Overload Level (Pn072).
---
---
---
---
16
@
Operation with a much higher
torque than the rated value
continued for several seconds
to several tens of seconds.
---
---
---
18
18
@
4012
Regeneration
overload
Regeneration energy
exceeded the processing abil-
ity of the regeneration resis-
tance.
---
---
---
21
21
@
4015
Encoder commu-
nications error
Communications between
encoder and Servo Drive have
failed for the specified number
of times, causing an error to be
detected. (No response to
request from Servo Drive.)
---
---
---
23
23
@
4017
Encoder commu-
nications data
error
Data communications error
has occurred, most likely due
to noise.
---
---
---
24
---
4018
Deviation counter
overflow
The number of position devia-
tion pulses exceeded the set-
ting for the Deviation Counter
Overflow Level (Pn209).
---
---
---
---
24
@
The number of pulses in the
error counter exceeded the
setting for the Error Counter
Overflow Level (Pn014).
Servo Drive display
Position
Control
Unit error
code
Error detection
function
Detected error or cause of
error
W
Series
W-series
(Built-in
Commu-
nica-
tions
Type)
SMART-
STEP Jun-
ior (Built-
in commu-
nications
Type)
G-Series
(Built-in
commu-
nica-
tions
Type)
G5-Series
(Built-in
commu-
nications
Type)
Summary of Contents for CX-MOTION-NCF - V1.9
Page 1: ...Cat No W436 E1 09 CX Motion NCF Ver 1 9 SYSMAC CXONE AL_C V3 CXONE AL_D V3 OPERATION MANUAL...
Page 2: ......
Page 3: ...CXONE AL C V3 CXONE AL D V3 CX Motion NCF Ver 1 9 Operation Manual Revised September 2009...
Page 4: ...iv...
Page 6: ...vi...
Page 20: ...xx...
Page 24: ...xxiv Application Precautions 5...
Page 36: ...12 Connecting to PLC Section 2 2...
Page 40: ...16 Screen Name Section 3 1 Monitor Windows Axis Monitor Window Unit Monitor Window...
Page 66: ...42 Editing Servo Parameters Section 5 2...
Page 71: ...47 Print Section 6 5 Print Samples An example of printed Unit Parameters is shown below...
Page 92: ...68 Writing to Flash Memory Section 7 6...
Page 106: ...82 Axis Monitor Section 8 2...
Page 112: ...88 Test Run Section 9 1...
Page 138: ...114 Troubleshooting Section 11 3...
Page 142: ...118 Index...
Page 146: ...122 Revision History...