Specifications
Section
1-3
45
CX-Process Monitor Specifications
Item
Descriptions
Product name
CX-Process
Model
WS02-LCTC1
Applicable PC-series
CS1 Series
Applicable Unit
Loop Control Unit
Personal computer
PC AT or compatible
CPU
Min. required: Pentium 133 MHz or faster, Recommended: Pentium MMX233
MHz or faster
OS
Microsoft Windows NT4.0 Service Pack 4 or later or Windows 2000 (Windows
95/98 cannot be used.)
Memory
Min. required: 64 Mbytes, Recommended: 96 Mbytes or more
Hard disk drive
Min. required: 150 Mbytes of free space, Recommended: 200 Mbytes or more
of free space
Monitor
Min. required: XGA, Recommended: XGA or higher, min. 1024 x 768 dots,
256 colors
CD-ROM drive
At least one
Mouse
Recommended: Microsoft mouse or compatible pointing device
Applicable
computer
Sound board
1 pce.
Connecting
method
Connection with CPU Unit
(or Serial Communications
Board/Unit)
When
FinsGateway
SerialUnit
version is
used.
The computer is connected to the CPU Unit peripheral ports or
integrated RS-232C port, or RS-232C port of the Serial
Communications Unit. (Only a 1:1 connection is possible.)
- Connector cable:
When connecting to the CPU Unit peripheral ports: Model
CS1W-CN
(2 m, 6 m)
When connecting to the CPU Unit’s RS-232C port: Model
XW2Z-
-
(2 m, 5 m)
(For details on model numbers, see 2-3 Connecting to CX-
Process Tool and CX-Process Monitor.
- Communications protocol with PC: Host Link (not supported
on Peripheral bus)
Connection via Controller
Link
When
FinsGateway
Controller
Link version
is used.
The FinsGateway Controller Link version is installed on the
computer on which the Controller Link Support Board is
mounted to enable communications with the PC on which the
Controller Link Unit is mounted.
Loop Control Unit data specification
method
Function blocks, analog signals and contact signals (including parameters)
that are designated as the source by the Send to Computer blocks (Block
Models 401 to 404) are appended a tag number by the CX-Process Tool.
Specify this tag number to specify the Loop Control Unit data.
When reading from the Loop Control Unit:
Use the terminal to computer send area in the Data Memory for the node
terminals on the CPU Unit.
When performing operations on the Loop Control Unit:
Write to the function blocks that are specified as the source designation in the
Send to Computer block without using the terminal to computer send area.
Note: Microsoft Windows NT4.0 is required for preparing tag data to be used
by the CX-Process Monitor. This data cannot be prepared on Windows
95/98.
Mode name
Description
Connection method
On-demand read
mode:
CX-Process Monitor reads the
data in the terminal to
computer send area whenever
necessary.
One of Host Link,
Ethernet or Controller
Link
Data exchange method with CPU Unit
mounted on Loop Control Unit
Data Link mode:
CX-Process Monitor reads the
terminal to computer send area
at all times by the Controller
Link data link.
Only Controller Link is
possible