033), Indicator block (Block Model 034), and 4-Point Warning Indicator
block (Block Model 110).
An SP Rate-of-change Limit Time Unit (ITEM 030) has been added to
the Advanced PID block (Block Model 012).
In the Batch Flowrate Capture block (Block Model 014, the following
ITEMs have been added: Local SP Setting, Upper 4 Digits (ITEM 024),
Remote SP Setting, Upper 4 Digits (ITEM 028), Current SP Value, Upper
4 Digits (ITEM 030), Preset Value, Upper 4 Digits (ITEM 061), and Batch
Accumulated Value, Upper 4 Digits (ITEM 065) because the number of
digits has been increased from 4 to 8 digits for the Local SP, Remote SP,
Preset Value, and Batch Accumulated Value.
A Time Unit (ITEM 013) was added to the Rate-of-change Limit block
(Block Model 143).
A Reference Input Disable Switch (ITEM 020) was added to the Segment
Program 2 block (Block Model 157) to enable starting from the initial
value rather than the reference input value even when the source of the
reference input is specified.
An Output Type (ITEM 006) was added to the Contact Distributor block
(Block Model 201) to enable selecting between a constant output and a
one-shot output.
Range settings were added for individual points for the AI Terminal from
CPU Unit block (Block Model 453), AO Terminal to CPU Unit block
(Block Model 454), Ai4 Terminal block (Block Model 561), Pi4 Terminal
block (Block Model 562), and Ai8 Terminal block (Block Model 564).
A Receive Disable Switch (ITEM 225) was added to the Expanded DI
Terminal from CPU Unit block (Block Model 455) and Expanded AI
Terminal from CPU Unit block (Block Model 457) and a Send Disable
Switch (ITEM 225) was added to the Expanded DO Terminal from CPU
Unit block (Block Model 456) and Expanded AO Terminal from CPU Unit
block (Block Model 458).
A limit was set for writing ITEMs during execution of autotuning for Basic
PID (Block Model 011) and Advanced PID (Block Model 012). (Although
there was previous no limit on writing ITEMs during autotuning, ITEMs
could not be written except while processing was disabled, autotuning
was specified or executing, or A/M was being switched.)
Floating point decimal data can now be specified as the source data for
inputs X1 to X8. (Previously, normalized data was specified for inputs X1
to X8 and this data was scaled to floating point data. The source data
was automatically detected as normalized or floating point data and
scaling was disabled if the source data was already floating point data.