Revision History
A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
Cat. No.
W374-E1-3
The following table outlines the changes made to the manual during each revision. Page numbers refer to the
previous version.
Revision code
Data
Revised content
1
March 2000
Original production
2
November 2000 Addition of the following function blocks and corrections made to errors.
ES100X Controller Terminal (Block Model 045)
4-point Warning Indicator (Block Model 110)
Arithmetic Operation (Block Model 126)
Time Sequence Data Statistics (Block Model 153)
Receive All Blocks (Block Model 461)
Send All Blocks (Block Model 462)
Addition of the following functions and corrections made to errors
DIP switch setting added to enable battery-free operation using flash memory.
RX-232C port application added for connection to ES100X Controller.
3
August 2001
Addition of the following function blocks and corrections made to errors.
Fuzzy Logic (Block Model 016)
Range Conversion (Block Model 127)
Ramped Switch (Block Model 167)
Level Check (Block Model 210)
AI4 Terminal (DRT1-AD04) (Block Model 588)
AO2Terminal (DRT1-DA02) (Block Model 589)
Addition of the following function block ITEMS and corrections made to errors
Block Registration Flag (ITEM 039) and Tool Version (ITEM 110) in System
Common (Block Model 000).
Warning Limit (ITEM 012) in Basic PID (Block Model 011, Advanced PID (Block
Model 020), 2-Position ON/OFF (Block Model 001), 3-Position ON/OFF (Block
Model 002), Indication and Setting (Block Model 031), Indication and Operation
(Block Model 032), Ratio Setting (Block Model 033), Indicator (Block Model 034),
and 4-Point Warning Indicator (Block Model 110).
SP Rate-of-change Limit Time Unit (ITEM 030) in Advanced PID (Block Model
012).
Local SP Setting, Upper 4 Digits (ITEM 024), Remote SP Setting, Upper 4 Digits
(ITEM 028), Current SP Value, Upper 4 Digits (ITEM 030), Preset Value, Upper 4
Digits (ITEM 061), and Batch Accumulated Value, Upper 4 Digits (ITEM 065) in
Batch Flowrate (Block Model 014).
Time Unit (ITEM 013) in Rate-of-change Limit (Block Model 143).
Reference Input Disable Switch (ITEM 020) in Segment Program 2 (Block Model
157).
Output Type (ITEM 006) in Contact Distributor (Block Model 201).
Range settings in AI Terminal from CPU Unit (Block Model 453), AO Terminal to
CPU Unit (Block Model 454), Ai4 Terminal (Block Model 561), Pi4 Terminal (Block
Model 562), and Ai8 Terminal (Block Model 564).
Receive Disable Switch (ITEM 225) in Expanded DI Terminal from CPU Unit (Block
Model 455) and Expanded AI Terminal from CPU Unit (Block Model 457) and Send
Disable Switch (ITEM 225) in Expanded DO Terminal from CPU Unit (Block Model
456) and Expanded AO Terminal from CPU Unit (Block Model 458).
Revision code