![Omron CK3M Series Hardware User Manual Download Page 260](http://html1.mh-extra.com/html/omron/ck3m-series/ck3m-series_hardware-user-manual_742506260.webp)
ID Type
Value (hex)
Instance ID 01
Attribute ID
The attribute IDs for instances are as shown below.
At-
trib-
ute
ID
(hex)
Parameter name
Description
Attrib-
ute
Data type
Value (hex)
01
Interface Speed
Gives the baud rate for the interface.
Read
UDINT
Current val-
ue
02
Interface Flags
Gives the status of the interface.
Read
DWORD
03
Physical Address
Gives the MAC address of the interface.
Read
ARRAY
OF USINT
Current val-
ue of the
MAC ad-
dress
04
Interface Counters
Path to the physical link object
Read
Struct
---
In Octets
The number of octets received through
the interface.
Read
UDINT
Current val-
ue
In Unicast Packets
The number of unicast packets received
through the interface.
Read
UDINT
Current val-
ue
In NonUnicast
Packets
The number of packets besides unicast
packets received through the interface.
Read
UDINT
Current val-
ue
In Discards
The number of packets discarded after re-
ceived by the interface
Read
UDINT
Current val-
ue
In Errors
The number of incoming packets that had
errors.
Read
UDINT
Current val-
ue
In Unknown Protos
The number of incoming packets that
were of an unknown protocol.
Read
UDINT
0 (always)
Out Octets
The number of octets sent through the in-
terface.
Read
UDINT
Current val-
ue
Out Unicast Pack-
ets
The number of unicast packets sent
through the interface.
Read
UDINT
Current val-
ue
Out NonUnicast
Packets
The number of packets besides unicast
packets sent through the interface.
Read
UDINT
Current val-
ue
Out Discards
The number of discarded sent packets.
Read
UDINT
Current val-
ue
Out Errors
The number of sent packets that had er-
rors.
Read
UDINT
Current val-
ue
05
Media Counters
Media counters for communications ports
Read
Struct
---
Alignment Errors
Number of frames received that were not
octets in length.
Read
UDINT
Current val-
ue
FCS Errors
Number of frames received that did not
pass the FCS check.
Read
UDINT
Current val-
ue
Single Collisions
Number of frames sent successfully with
only one collision.
Read
UDINT
Current val-
ue
Multiple Collisions
Number of frames sent successfully with
two or more collisions.
Read
UDINT
Current val-
ue
Appendices
A-18
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
Summary of Contents for CK3M Series
Page 6: ...Manual Structure 4 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Page 284: ...Appendices A 42 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Page 285: ...I Index I 1 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036 I...
Page 287: ......