![Omron CK3M Series Hardware User Manual Download Page 137](http://html1.mh-extra.com/html/omron/ck3m-series/ck3m-series_hardware-user-manual_742506137.webp)
3
Establish an SSH connection, and execute the
sync
command from the terminal that you con-
nected to.
4
Wait for at least 5 seconds and turn OFF the power supply.
Procedure to Download to the Built-in Flash Memory (Version 2.5 or Later)
For PMAC firmware revision version 2.5 or later, you can also use the following procedure to store
the user program into the built-in flash memory.
1
Download the user program from the Power PMAC IDE.
2
At the Power PMAC IDE terminal, enter
Sys.SyncSave=1
.
3
At the Power PMAC IDE terminal, execute the
save
command.
Wait until the save completed notification is displayed on the Power PMAC IDE.
4
At the Power PMAC IDE terminal, enter
Sys.SyncSave=0
.
5
Wait for at least 5 seconds and turn OFF the power supply.
4 Installation
4-3
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
4-1 Processing at Power ON and Power OFF
4
4-1-2
Power OFF Operation