![Omron CK3M Series Hardware User Manual Download Page 218](http://html1.mh-extra.com/html/omron/ck3m-series/ck3m-series_hardware-user-manual_742506218.webp)
OFF
OFF
ON
ON
ECAT LINK
(orange)
Ethernet LINK
(orange)
EtherCAT physical layer link not
established
Ethernet physical layer link not
established
DA output, DirectPWM output
and encoder power supply from
CK3W-AX Unit not output
Error details cannot be deter-
mined solely by checking LEDs.
*1
Non-fatal errors in the CPU Unit
Interrupted communications
between Power PMAC IDE and
Programmable Multi-Axis Controller
Analog values from CK3W-AD
Unit not converted correctly
EtherNet/IP connection not
established
A
B
Position data for encoder
connected to CK3W-ECS Unit
not converted correctly
Position and ON/OFF of laser
connected to CK3W-GC Unit not
operating correctly
*1. For the details of errors that cannot be determined solely by checking the indicators, check the Sys.Status
register.
Refer to
6-4-1 Sys.Status Register List
on page 6-10 for the Sys.Status flag.