SECTION 3 |
11
INSTALLATION
Ethernet Connections
There are two 10/100 Ethernet ports on the rear panel; one interface is for control, the second is for L/
AES67 AoIP. Connect these ports to your network switches as appropriate. If you do not connect the VOCO 8 to
an existing network, you will need a cable connected directly from the control port to a Windows PC for initial
configuration of the unit (see the “Remote Gateway Software” section of this manual for further details).
AC Power Connections
The VOCO 8 features redundant power supplies. This is to accommodate facilities with dual power feeds to
each equipment rack fed from completely independent sources. Both inputs should be connected, preferably to
completely separate AC power sources such as conditioned utility power and UPS/generator, or at the very least
two different circuits in a rack. While the unit will still function with only one power supply connected, an error
message will be displayed on the LCD and in the remote software.