![Omnia voco 8 User Manual Download Page 16](http://html2.mh-extra.com/html/omnia/voco-8/voco-8_user-manual_4015903016.webp)
SECTION 3 |
7
INSTALLATION
Mic/Line Inputs and Outputs
Each of the 8 analog inputs can accept either a microphone level signal (with selectable Phantom power and pad)
or a line level signal. Input connections are provided through a set of Neutrik “combo” connectors (pin 2 hot; tip
hot). Analog inputs and outputs are also provided on a pair of female DB25 connectors conforming to the Tascam
standard pinout.