7000 SERIES INDICATORS
EN 73
2.
Use the arrow keys to select the Target Table icon
, then press
ENTER
.
3.
The first record from the Target Table will appear. The data in each record will vary depending on the selected
tolerance mode:
a)
If Tolerance = % of Target Value or Weight Deviation, the fields are:
ID, Description, Target, Units, -Tol, +Tol
b)
If Tolerance = Weight Value, the fields are:
ID, Description, Units, Under Limit, Over Limit.
4.
Use the UP and DOWN arrows to move focus from one record to the next until the desired record is shown.
Press
ENTER
to select it and return to the Checkweighing run display, or the
LEFT
arrow to return to
the Operator Menu without selecting a new set of target parameters.
Quick Recall From Target Table
If the ID of the Target Table record is known, the record can be recalled without accessing the Operator Menu:
1.
Use the keypad to begin to enter the alphanumeric ID number. The screen will show the Data: label on line 1,
and the entered value on line 2 of the display.
2.
When the entire ID has been entered, press ID
to recall the record.
3.
If the ID exists, the application will use the new parameters. If the ID is not found, an error message will
appear
– ID not found. Clear the message by pressing
ENTER
. The display will return to the
checkweighing application, using the previous target parameters.
Setup Mode Target Entry
This entry mode is described in the Target Values configuration section, on page 69.
4.3.5
Print Formats
When a demand print is triggered in the Checkweighing application, the indicator will look for a demand connection
to one of the ports using template 6. If such a connection exists, then template 6 will be sent out the selected port.
If there is no demand connection using template 6, a “No demand connection” error will be displayed.
New Print Fields
Template 6 contains seven new data fields related to the Checkweighing application that are not available in the
other templates. These new print fields are:
n (count of totalization by ID)
Target Description
Target ID (from Target Table)
Target Weight
Target and Tolerances
Total (totalized weight by ID)
Zone (text for the active zone
– Under, OK, Over)
Default Template
The default format for template 6 is shown in Figure 4-7
. Elements in braces {…} are fields of data supplied by the
indicator. Figure 4-8 shows the resulting print.
{String 1} {New line}
{String 2} {New line}
{Time} {3 spaces} {3 spaces} {Date} {New line}
{Transaction #} {New line}
{Target Description} {New line}
{Displayed Weight} {New line}
{End of template}
Figure 4-7: Default Structure of Template 6
www.
GlobalTestSupply
.com
Find Quality Products Online at:
Summary of Contents for T72XW AM
Page 2: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Page 3: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Page 4: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Page 8: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Page 142: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...