EN 56
7000 SERIES INDICATORS
Ethernet is available for transfer of dataand connection to a Print Client. Setup for Ethernet allows static Internet
Protocol (IP) addressing only.
The Ethernet branch includes the following fields:
MAC Address
The Medium Access Control (MAC) Address cannot be edited; it is shown for information only.
DHCP Client
The DHCP (Dynamic Host Configuration Protocol) client can be Enabled or Disabled. If the DHCP Client setting is
enabled, the IP Address, Subnet Mask, and Gateway Address fields are assigned automatically by the network and
become read-only in the setup screens. If disabled, the IP address must manually be assigned in the following
fields.
IP Address
Enter the IP address (or view if DHCP Client is enabled) for the T72XW indicator. After each group of digits has
been entered, press
ENTER
to proceed to the next group. The default value for the IP is 192.168.000.001.
Subnet Mask
Enter the subnet mask (or view if DHCP Client is enabled) for the T72XW indicator. After each group of digits has
been entered, press
ENTER
to proceed to the next group. The default value for the subnet mask is 255.255.255.0.
Gateway Address
Enter the gateway address (or view if DHCP Client is enabled) for the T72XW indicator. After each group of digits
has been entered, press
ENTER
to proceed to the next group. The default value for the gateway is blank.
After entry is complete, press the
LEFT
navigation key to return to the setup menu
Print Client
The Print Client connection allows the T72XW to send data to a network device such as a printer. The Print Client
configuration is only shown if a print client connection was created at Communication > Connections > Ethernet.
Server IP Address
The Server IP Address is the IP address of the network device (usually a printer) where the indicator will send the
print information. Enter the IP address using the numeric keypad.
Server TCP Port
Enter the Server TCP Port of the device on the network. This is the port on the network device through which
communication is established.
Reset
To initiate a reset of the Communication block of setup, press the
ENTER
key. If the reset was successful, a
verification message that reads “Reset Successful” displays If the reset was not successful, an error message that
reads “Reset Failure” displays. If the reset fails, try to initiate the reset again. If the reset continues to fail, contact a
local OHAUS CORPORATION representative for assistance.
Press the
LEFT
navigation key to exit without resetting.
3.5.5
Maintenance
A detailed view of the Maintenance branch is shown in Figure 3-17. This view indicates all the parameters in the
Maintenance branch. Each of these setup parameters are described in this section.
www.
GlobalTestSupply
.com
Find Quality Products Online at:
Summary of Contents for T72XW AM
Page 2: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Page 3: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Page 4: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Page 8: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...
Page 142: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...