Chapter 10 Troubleshooting
CPT7 and CPT7700 Installation and Operation User Manual v12
135
Bit Set
Action to Resolve
4
Contact
5
Check the
VERSION
log. The VERSION log will indicate "Invalid authcode". Upgrade the auth-code
as described in
6
Issue a
FRESET
command
7
See
Power Supply Requirements for the CPT7
8
Reserved
9
Check the temperature ranges in:
l
CPT7 Electrical and Environmental Specifications
The operating temperatures are ambient air temperatures. The temperature sensors
on the receiver PCB will reflect higher operating temperatures (refer to the
HWMONITOR
log). The PCB temperature sensors will trigger a receiver warning and
receiver error at 100°C and 110°C respectively. The warning and error conditions are
captured using the
RXSTATUS
log.
10
Possible hardware or environmental condition. If you cannot resolve the problem, contact
11
Possible hardware or environmental condition. If you cannot resolve the problem, contact
Also, check the Auxiliary 2 Status word to determine which PLL is in error.
12-14
Reserved
15
Issue a
FRESET
command and power cycle the unit. If the bit is still present, contact
16
Monitor CPU idle time. Reduce number of logs or the rate of data logging.
17
Ensure that the Version log is consistent with the hardware.
18-19
Reserved
20
SoftLoad is in progress. See
Updating Using SoftLoad Commands
21
You may be exceeding the receiver’s velocity limit. If so, reduce velocity. This error can only be
cleared by resetting the receiver.
22
Reload firmware using WinLoad or the SoftLoad commands.
23-30
Reserved
31
Possible hardware failure. Contact