4-8
Air Pressure Settings
See Figure 4-4 and Figure 4-5, and refer to the table below. Refer to the
Drawings
section for feed center pneumatic diagrams.
Item
Function
Recommended Pressure
1
Lift Cylinder Down
3.4 bar (50 psi) 0.34 Mpa
2
Lift Cylinder Up
Lance: 4.1 bar (60 psi) 0.41 Mpa
Lances: 4.8 bar (70 psi) 0.48 Mpa
Lances: 5.5 bar (80 psi) 0.55 Mpa
−
Lift Cylinder Flow Control Valves
6 seconds full travel both directions
3
Purge Air
6.2 bar (90 psi) 0.62 Mpa
4
Lance Purge Clamp
3.4−4.1 bar (50−60 psi) 0.34−0.41 Mpa
−
Clamp Cylinder Flow Control Valves
3 seconds full travel both directions
5
Feed Hopper Fluidizing
0.3−0.7 bar (5−10 psi) (see Note)
0.03−0.06 Mpa
6
Lance Fluidizing
0.3−0.7 bar (5−10 psi) (see Note)
0.03−0.06 Mpa
NOTE:
Adjust fluidizing air as needed. Powder should be gently boiling, without geysering.