Lance Assembly/Purge Manifold Alignment (contd)
5. Set the purge air pressure to zero.
6. Move the lance down to the stop bolt (Purge Position). Verify that the stop bolt is
adjusted to stop the carriage just before the lance makes contact with the purge
manifold quad-ring seals. Manual alignment of the lances to the purge manifolds may
be necessary as all the fasteners are loose.
Quad-Ring Seals
Jam Nut
Stop Bolt
Carriage
Figure 8-10 Stop Bolt Adjustment
7. Turn the Purge Control switch to the Internal Gun Purge position. The lance will be
clamped into place.