© 2021 Nordson Corporation
10-8
VIBRASONICS/POWER Indicator Troubleshooting
Use the following chart to correct fault conditions indicated by the POWER and
VIBRASONICS indicators.
Indicator Status
Possible Cause
Corrective Action
POWER: on
VIBRASONICS: off
Faulty indicator bulb
Check the indicator light bulb and replace if necessary.
Loose cable connection
Check all cable connections.
Poor contact surfaces
between transducer and
sieve screen
Remove the transducer from the screen and clean the mating
surfaces with acetone. Assemble the transducer to the screen
using the
Vibrasonic Transducer and Sieve Screen Installation
procedure.
POWER: off
VIBRASONICS: off
Controller power is off
Turn on power to the controller.
Circuit breaker tripped
Open the controller and reset the miniature circuit breaker.
Faulty indicator bulbs
Check the indicator light bulbs and replace if necessary.
POWER: off
VIBRASONICS: on
Faulty indicator bulb
Check the indicator light bulb and replace if necessary.
POWER: on
VIBRASONICS: flashing
Break in continuity or
change in polarity in
control or transducer
cable
Turn off controller power and check the transducer cap screw for
the proper torque. Turn on controller power and check indicators.
If the condition persists, replace the cables.
Summary of Contents for Encore XL Powder
Page 8: ...2021 Nordson Corporation 1607027 01 ii Change Record...
Page 12: ...2021 Nordson Corporation 1607027 01 1 4 Safety...
Page 51: ...2021 Nordson Corporation 1607027 01 4 9 Setup 6 5 Figure 4 5 Pneumatic Controls 2 of 2...
Page 60: ...2021 Nordson Corporation 1607027 01 5 8 Operation...
Page 136: ...2021 Nordson Corporation 1607027 01 9 34 Parts...
Page 146: ...2021 Nordson Corporation 1607027 01 10 10Options...
Page 148: ...2021 Nordson Corporation 1607027 01 11 2 Pneumatic and Electrical Diagrams...
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ...ON OFF...
Page 154: ......