© 2021 Nordson Corporation
2-14
Control Manifold Functions
The control manifold controls most of the pneumatic equipment in the feed center. It is
connected to the feed center control panel by a single cable.
AIR IN
CABLE
RECEPTACLE
AIR IN
MUFFLERS
(EXHAUST AIR)
Closed
Open
Extend
Retract
9 8 7 6 5 4 3 2 1
Figure 2-10 Control Manifold Functions
Valve No.
Solenoid Designation
Function
1
SOL 325/0
Lance Up (vented when energized, allowing Lance Up)
2
SOL 325/1
Lance Down (vented when energized, allowing Lance Down)
3
SOL 326
Lance Lock (energized to unlock cylinder, vented to lock cylinder)
4
SOL 331
Purge Clamp (extend/retract)
5
SOL 342
HDLV Virgin Pump Purge
6
SOL 338
HDLV Virgin Pump On
7
SOL 340
HDLV Reclaim Pump Purge
8
SOL 336
HDLV Reclaim Pump On
9
SOL 329
Damper (open/closed)